20" DOUBLE JUMBO + UV STERILIZER

Category: Central Systems
0 AED

20" DOUBLE JUMBO + UV STERILIZER



Specifications
Name 20" DOUBLE JUMBO + UV STERILIZER
Brand Hawk ACT
Code 309766
Barcode 758486058
Description

AQFBB20-TWIN-UV12HT1
DUAL FILTRATION WITH 12GPM UV STERILIZER
PROVIDE 2500~3000LPH STERILIZED WATER
SAFE AND CHEMICAL FREE
UV LAMP PROVIDES CONSISTENT UV OUTPUT OVER 9000HRS
ELECTRONIC BALLST VISUALLY DISPLAYS UV FUNCTION
ACCUMULATED TIMER UP TO 99999HRS

MAIN PARTS LIST   

BK-2BB-STAND-20        BRACKET FOR 2 * 20" BIG BLUE                                               HOUSINGS


AQF-2050BU-1NPT-X    5U PP SPUN FIBER FOR 20" BIG                                                BLUE HOUSING, NSF 

FL-PPS-2045                  5U PP SPUN FIBER FOR 20" BIG                                                BLUE HOUSING, NSF  


APC-2045                      CARBON BLOCK CARTRIDGE FOR                                           20" BIG BLUE HOUSING   

GAUGE-V-15B              GAUGE, VERTICAL TYPE, 0-15BAR,                                          0-200PSI

UV-12GPM-HT1           12GPM UV STERILIZER, WITH                                                   TIMER  BALLAST

CN-L-88M88HP           CONNECTOR, 1" MALE X 1" HP                                                 TUBE, ELBOW (OPTION)


INSTALLATION & REPLACEMENT

INSTALLATION STEPS:
1. Fix the system at the proper location.
2. Connect the water pipe to the Inlet 1"
3. Take the UV lamp out and connect it with a black covered plug(try if ok), then remove it.
 Put the lamp into the UV chamber, connect it with the plug, and well cover the end cap.
4. Fix the grounding.
5. UV plugged into the power supply
6. Check if the Green lamp is "on" on the ballast.
7. Check the filter housing's cap is locked tightly.
8. Turn on the water supply, and push the "red" button to release the air, there will be some water dripping out, about 3 times, then the installation is completed.

 

UV BALLAST: CHECKLIST 

Lamp green: on, normal
Lamp red: flashing & beeping - replace lamp
Lamp green & red off:
1. Out of electricity, or other power supply problem
 Should recover when electricity supplies again.
2. Environment or system temp over 80˚C.
 Temperature protection will shut off the ball.
 Please plug off the UV for at least 15 minutes and plug again.
3. Fuse damage
 A stable electricity supply is necessary for a UV sterilizer.
 If the fuse is damaged, should replace a new ballast.
 The damaged ballast please send back to the shop to check fuse burned off reason &
 recommend the improvement, otherwise, the same damage will continue

CARTRIDGE REPLACEMENT:
1. The water quality is varied in every location, so the 2 gauges will be important
 for replacement reference.
2. The gauge located at the right inlet housing is showing the "inlet water pressure"
 The gauge located at the left outlet housing is showing the "product water pressure"
 If the reading on both gauges, with the difference of 1 bar (14.7psi-15psi), please
 replace the new cartridges.

 

LAMP REPLACEMENT
1. Stop the water supply and remove the UV plug from the electric socket.
2. Loosen the Hex nut to release water inside the chamber.
3. If need to dismantle the UV chamber, the special clamp will open when pushing the UV
 chamber inward.
4. Remove the used lamp from the black covered socket, and replace it with the new lamp.